30.7 Unless the meter is being used to measure leakage from one part of a pump to another, the meter
is to be connected between the accessible parts and the grounded supply conductor.
30.7.1 A submersible pump is to be tested for leakage current while submersed in a tank filled with water.
The top of the pump is to be at least 12 inches (305 mm) below the surface of the water during the test.
The test tank shall be isolated from ground and the meter is to be connected between the grounding
conductor and the grounded supply conductor of the flexible supply cord.
30.7.1 added March 29, 1999
30.8 A sample of the pump is to be tested for leakage current starting with the as-received condition with
all switches closed, but with the grounding conductor open at the attachment plug. The as-received
condition is without prior energization except as may occur as part of the production-line testing. The
supply voltage is to be 120 or 240 volts as appropriate, depending upon the rated voltage of the pump.
The test sequence, with reference to Figure 30.1 is to be as follows:
a) With switch S1 open, the pump is to be connected to the measuring circuit. Leakage current
is to be measured using both positions of switch S2, and with the pump switching devices in all
normal operating positions.
b) Switch S1 is then to be closed, energizing the pump, and within 5 seconds, the leakage
current is to be measured using both positions of switch S2, and with the switching devices on
the pump in all their normal operating positions.
c) Leakage current is to be monitored until thermal stabilization. Both positions of switch S2 are
to be used in determining these measurements. Thermal stabilization is to be obtained by
operation of the pump as in the normal temperature test.
30.9 Normally, the complete leakage-current test described in 30.8 shall be conducted without
interruption for other tests. However, with the concurrence of those concerned, the leakage-current tests
may be interrupted for the purpose of conducting other nondestructive tests.
30.10 A permanently connected pump need not be subjected to the leakage current test if all accessible
metal parts are connected to the grounding means.