Table 44.2 Continued
Horsepower 110 120 volts 220 240 volts 550 600 volts
7-1/2 58.0 29.0 12.0
10 76.0 38.0 16.0
15 112.0 55.0 23.0
45 Strain Relief Tests
45.1 When tested in accordance with 45.2, the strain-relief means provided on a flexible cord is to
withstand for 1 minute, without displacement of the cord, a direct force of 35 pounds (156 N) applied to
the cord with the connections within the pump severed.
45.2 A 35 pound (15.9 kg) weight is to be suspended from the cord and supported by the pump so that
the strain-relief means is stressed from any angle that the construction of the pump permits. The strain
relief is not acceptable if, at the point of disconnection of the conductors, there is such movement of the
cord as to indicate that stress would have resulted on the connections or the watertight seal is damaged.
45.3 Strain relief at the entrance of a cord or cable of a contractor-type pump shall support the pump for
1 minute without damage to the seal or transmission of stress to the internal connections.
45.4 Strain relief at the entrance of deep-well cable to a deep-well, submersible-type pump shall
withstand a 35 pound (156 N) force applied to each conductor for 1 minute without damage to the seal or
transmission of stress to the internal connections. The test shall be conducted on each conductor of a
twisted-singles construction and on the complete cable of the integral parallel conductor type.
46 Operation Test
46.1 Operation of a pump as described in 46.2 shall not increase the risk of fire, electric shock, or injury
to persons.
46.2 With reference to 46.1, an as-received sample of the pump is to be set up or installed in accordance
with the manufacturer’s instructions. The sample is to be operated in accordance with the manufacturer’s
instructions with regard to the intended uses of the pump, including maintenance and cleaning
recommended by the manufacturer and lack of such maintenance and cleaning, and with all accessories
recommended by the manufacturer for use with the pump. The pump is to be manipulated as it would be
in actual use, including manipulation of all controls and operation under the various loading conditions that
can be expected. The pump is to be operated only for the length of time, or number of cycles needed to
determine the appropriateness of the manufacturer’s instructions.